13.REGULATOR ADJUSTMENT KNOB FOR UMBILICAL PRESSURE (H)
The regulator Adjustment Knob (H) allows the operator to adjust the umbilical pressure within a range of 115 psi to 225 psi
14.OUTLET MANIFOLD INCLUDING DIVER’S UMBILICAL FITTINGS (G)
The “WHITE DIVER” and “RED DIVER” air supply hoses are connected to the KMACS 5 at the manifold (G). The fittings coming out of the KMACS 5 are male #6 JIC (3/8”, 37°) flared fittings. The diver’s air supply hoses must have matching female #6 JIC flared fittings with swivel nuts.
The “WHITE DIVER” and “RED DIVER” pneumo- fathometer hoses are also connected to the KMACS 5 at the manifold (G). The fittings coming out of the KMACS 5 are male #4 JIC ( 1/4”, 37°) flared fittings. The diver’s pneumofathometer hoses must have matching female #4 JIC (1/4”, 37°) flared fit- tings with swivel nuts.
15.PNEUMO VALVE KNOB, WHITE DIVER
(O)
The Pneumo Valve Knob, White Diver turns on and off the air supply to the “WHITE” pneumofathometer system.
16.PNEUMO VALVE KNOB, RED DIVER
(D)
The Pneumo Valve Knob, Red Diver turns on and off the air supply to the “RED” pneumofathometer system.
KMACS 5 MANUAL
17. O-RING SEAL (U)
The
18. COMMUNICATOR PANEL (V)
The diver’s electronic communicator (R) is attached to the communicator panel. The battery for the com- municator is located behind this panel.
19. COMMUNICATOR (R)
The
CAUTION: Never connect the charger during a dive or when anyone is in contact with connected equipment. Although electrical shock danger is remote, connection of the recharging cord should only be done when the KMACS 5 is not in use.