Before you start...
Check location where hot water dispenser will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with installation specifications provided and with state and local plumbing codes.
Faucet mounting: requires a
Electrical Shock Hazard Special care must be taken when drilling holes into walls or water pipes. Electrical wires may be concealed behind the wall covering or water may remain in pipes.
Failure to follow this instruction could result in personal injury or death.
Personal Injury Hazard
Install faucet with lever to the side or behind spout.
Failure to do so may result in hot water scalding hand when operating lever.
NOTE:
This hot water dispenser is Not a water purifier. Some installations may require a filter (such as charcoal) for increased satisfaction.
Dimensions shown must be used.
Proper cold water supply connection must be available. (See “Watersupply requirements,” Panel B.)
Use saddle tapping valve supplied. Saddle tapping valve is designed for use with 3/8” to l- 3/8” outer dimension (O.D.), soft copper tubing (plain or chrome plated) or rigid metal pipe. Do Not use the saddle valve with flexible ribbed tubing. (See “Watersupply requirements,” Panels B.) Flexible ribbed tubing requires special connecting hardware available from your local plumbing
supply.
Grounded electrical outlet is required. (See “Electrical requirements,” Panel B.) Outlet should be located for easy connection to hot water dispenser. The outlet should be within 30” of hot water dispenser tank.
Property/Product Damage
l Contact a qualified installer or licensed plumber for the best procedure for cutting a faucet opening in your type of sink or countertop.
l Plumbing connections must comply with all sanitary, safety and plumbing codes.
l Do Not store or operate hot water dispenser below 32°F.
l Do Not use pipe sealing compounds. They may get inside dispenser and cause an unpleasant taste or smell.
l Dispenser must be filled with water and thermostat turned to “OFF” position before connecting to electrical power
supply-
Failure to follow these instructions may result in water damage to property or permanent product damage not covered by the warranty.
Water connections use compression fittings which do Not require sealing compounds to keep them
Top view
Important: Observe all governing ordinances.
from leaking.
codes and
Faucet mounted in existing
install faucet with lever to the side or behind spout.
lever
spout
sink or countertop
hole
Cold water line
30”
Panel A
.-