15
2. Remove packing from around burner. 3. Remove plastic bags from grate and film from cover.
4. Reinstall grate.
5. Dispose of/recycle all packaging materials.
6. Go to the “Check and Adjust the Burners” section.
GAS CONVERSIONS

Tools and Parts for Gas Conversion

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tool s n ee de d

Parts supplied

Brass connector
Convertible regulator 4" (10.2 cm) W.C. Natural, 11" (28 cm)
W.C. L P
Natural gas orifices
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical
power.
This kit is designed for use from sea level up to 2000 ft elevation.
For higher elevations contact KitchenAid at 1-800-422-1230 in
the U.S.A. or call 1-800-607-6777 in Canada.

Conversion to a Local LP Gas Supply

Installation of the regulator

1. Turn off the main gas supply valve.
2. Unplug Power™ burner or disconnect power.
3. Disconnect 20lb LP gas fuel tank (if present).
4. Turn off all burner control valves.
Phillips screwdriver
Pipe wrench
Adjustable wrench
7 mm socket and wrench
or 7 mm nut driver
Thin flat-blade screwdriver
Pliers
Pipe thread sealant
certified for LP gas
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11” (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.