Built-in Outdoor Grill Enclosure Ventilation for LP Gas:
An enclosure for an LP gas fuel tank is to be ventilated by openings at both the top and lower levels of the enclosure.
If converting to LP gas these vents are to be in the enclosure:
An enclosure for use with an LP gas fuel tank for
A
It is recommended that a separate circuit servicing only this grill be provided.
The model/serial number rating plate is located on the
20 in.2 (129.0 cm2) min. ventilation both sides
1" (2.5 cm) max.
10 in.2 (64.5 cm2) min. ventilation both sides
5" (12.7 cm) max.
5" (12.7 cm) max.
A
A. Model/serial number plate
Recommended Ground Method
The outdoor grill, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Check with a qualified electrician if you are not sure whether the grill is properly grounded.
8501 East Pleasant Valley Rd.
Cleveland, Ohio
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
B
A
C
A.
B.
C.Ground prong
7