Category II2H3+
Electric Power: 230 V - 50 Hz

If a hood is to be installed above the hob, refer to the hood

installation instructions to ensure the correct height above

the hob.

Hood and cabinetry clearances (mm)Injector table

6

Type of gas used Type of
burner Injector
label Control
primary air
(X)(mm)
Nominal
heat flow
kW
Nominal
consumption Reduced
heat flow
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
wok
fast
semi-fast
auxiliary
145
128
95
78
6
-
-
-
4,20
3,00
1,65
1,00
400 l/h
286 l/h
157 l/h
95 l/h
1,40
0,90
0,40
0,30
17 20 25
LIQUID
PETROLEUM
GAS (Butane)
G30
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
305 g/h
218 g/h
120 g/h
73 g/h
1,40
0,90
0,40
0,30
20 28-30 35
LIQUID
PETROLEUM
GAS (Propane)
G31
wok
fast
semi-fast
auxiliary
100
85
65
50
11
-
-
-
4,20
3,00
1,65
1,00
300 g/h
214 g/h
118 g/h
71 g/h
1,40
0,90
0,35
0,30
25 37 45
Type of gas used Configuration model Nominal heat flow kW Overall nominal
consumption Required air (m3) for
the combustion 1 m3of
gas
G2020 mbar 5 burners 11,50 1090 l/h 9,52
G3028-30 mbar 5 burners 11,50 836 g/h 30,94
G3137 mbar 5 burners 11,50 821 g/h 23,80