5-7
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
DOOR SWITCHWATER VALVE SOLENOID
Refer to page 4-22 for the procedure for servic-
ing the water valve.
1. Unplug the refrigerator or disconnect the
power.
2. Disconnect the wire connectors from the
water valve solenoid terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test probes to the
terminals of the ice maker solenoid. The
ohmmeter should indicate approximately
160 to 170 .
5. Touch the ohmmeter test probes to the
terminals of the water dispenser solenoid.
The ohmmeter should indicate approxi-
mately 330 to 355 .
Ice Maker Solenoid (1/4 Outlet)
Water Dispenser Solenoid (5/16 Outlet)
Refer to page 4-5 for the procedure for servic-
ing a door switch.
1. Unplug the refrigerator or disconnect the
power.
2. Disconnect one of the wires going to the
door switch.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test probes to the
door switch terminals.
5. The meter should indicate continuity (0 ).
NOTE: The door switches are normally-
closed.
6. Press the door switch actuator button and
the meter should indicate an open circuit
(infinite).