5-6
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-9 for the procedure for servic-
ing the crush/cube solenoid.
1. Unplug the refrigerator or disconnect the
power.
2. Disconnect one of the wires going to the
solenoid.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test probes to the
solenoid terminals.
5. The meter should indicate approximately
35 to 45 ohms.
CRUSH/CUBE SOLENOID ICE MAKER AUGER MOTOR
Refer to page 4-9 for the procedure for servic-
ing the ice maker auger motor.
1. Unplug the refrigerator or disconnect the
power.
2. Disconnect one of the wires going to the
auger motor.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test probes to the
auger motor terminals.
5. The meter should indicate approximately
2 to 4 ohms.