Make Electrical Connection

Make Electrical Connection

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect electrical power at the fuse box or circuit breaker box before installing dishwasher.

Failure to do so can result in death or electrical shock.

1.Remove screw securing the electrical box cover. Remove cover.

Connect ground wire to green ground connector in terminal box.WARNING

Electrical Shock Hazard

Electrically ground dishwasher.

Connect ground wire to green ground connector in terminal box.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

3.Connect wires as follows using twist-on connectors sized to connect direct wire to 16 gauge dishwasher wire.

Power supply wire:

 

Terminal box wire:

white

 

white

black

 

black

ground wire

 

ground connector

4.Attach ground wire to the green ground screw.

2.Route electrical wires through strain relief and secure to electrical plate.

A

B

A. Attach ground wire to green screw. B. Attach white and black wires.