21nit Wiring Diagrams
This model operates at 115 volts except for the cutter grid circuit which operates at 8.5 volts at 1 amp.
The compressor runs at all times except when the Bin Thermostat becomes satisfied and opens the circuit. This
Under normal operating conditions, when the evaporator reaches the preset tempera- ture (+lO” to
Electrical Shock Hazard
Disconnect power before servicing unit.
Failure to do so could result in electrical shock.
NOTE: Maximum fuse size: 15 amps.
Check Operation
a0 Start the unit by turning the service switch to “ON”and opening the line water valve.
tH NOTE: Left is “OFF’ - Middle is “ON”- Right is “CLEAN.” In ‘CLEAN” position, only the pump operates.
dCheck condenser fan to make sure it is revolving. Check for airflow. Do not insert hand into fan area.
dWater will not enter pump pan until freezing plate gets cold and machine goes into a harvest cycle.
d Check for even water flow over freez- ing plate. Unit must be level for proper operation.
dCheck for desired cube thickness and after 24 hours adjust if necessary. Maximum ice yield will be obtained with ice thickness at l/i’ (13 mm) to %” (16 mm).
d Replace grille.
11