If connecting to a 4-wire system:
This range is manufactured with the ground connected to the cabinet. The ground must be revised so the green ground wire of the
Grounding through the neutral conductor is prohibited for new
When a
The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper
2
1
1
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed,
3-wire receptacle (10-50R)
Electrical Requirements - Canada Only
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance with the CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■Check with a qualified electrical installer if you are not sure the range is properly grounded.
■When a
■A
■This range is equipped with a CSA International Certified Power Cord intended to be plugged into a standard
■Do not use an extension cord.