Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect
Reconnect the
Failure to follow these instructions can result in death or serious burns to children and adults.
1.Turn manual shutoff valve to the closed position.
2.Unplug range or disconnect power.
B
A
C
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the |
access cap counterclockwise. |
3.Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) water column above the set pressure. The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:
Natural Gas:
Minimum pressure 6" (15.2 cm) WCP Maximum pressure 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
To Convert Surface Burners
1.If installed, remove the burner grates.
2.Remove burner cap.
3.Remove the burner head.
NOTE: A ⁷⁄₈" socket must be used to remove the burner head of the large dual burners.
4.Using a T15 Torx® screwdriver, remove the burner base.
ALarge Dual Burner
B
A. Burner cap
C
B. Burner head
2. Remove spring retainer from the cap by pushing against the |
flat side of the spring retainer. Look at the spring retainer to |
locate the “LP” or “NAT” position. Turn over the spring |
retainer so the “NAT” is showing on the bottom. Snap the |
spring retainer back into the cap. Reinstall the cap onto the |
regulator. |
A
B
E | D | C |
A. Access cap |
| D. NAT position |
B. Gasket |
| E. LP position |
C. Gas pressure regulator
C. Gas opening
DD. Burner base
AMedium Burner A. Burner cap
BB. Burner head
C | C. Gas opening |
DD. Burner base
ASmall Burner
| A. Burner cap |
B | B. Gas opening |
| C. Burner base |
C
22