Kobe Range Hoods CH2236SQ, CH2230SQ Under The Cabinet Installation - Top Vent

Models: CH2230SQ CH2236SQ

1 31
Download 31 pages 47.94 Kb
Page 8
Image 8
UNDER THE CABINET INSTALLATION – TOP VENT

UNDER THE CABINET INSTALLATION – TOP VENT

Preparation before Installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.

-Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.

-A straight, short venting run will allow the hood to perform more efficiently.

-Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.

-Temporarily wire the hood to test for proper operation before installing.

-Peel protective film off the hood (if any).

-For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 2.

-Measure and create access opening for electrical wires under the cabinet.

-Cut the multi duct exhaust according to the size of the venting pipe. Refer to Figure 3.

Figure 1

Figure 2

Figure 3

6” Round Vent

7” Round Vent

3-1/4” x 10” Vent

 

 

 

Hood Installation

CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.

1.Puncture the knockout holes on the hood as shown in Figure 4.

6

Page 8
Image 8
Kobe Range Hoods CH2236SQ, CH2230SQ installation instructions Under The Cabinet Installation - Top Vent