-If necessary, attach two rubber stands (provided) with two (4x8 mm) screws (provided) to the back of the hood.

-Attach the hood-mounting bracket to the back of the hood with nine (3/16” x 3/8”) screws (provided) as shown in Figure 25.

Hood Installation

CAUTION: If required to move the cooking range to install the hood, turn OFF the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.

1.Using references on Table 2 and measurements on page 21-22, mark the leveling point of the hood. Position two mounting screws (not provided) on the wall, leaving 1/8” away from the wall as shown in Figure 26.

Mounting

Screws

Figure 25

Figure 26

2.Use aluminum or steel pipe to connect the exhaust opening at the rear of the hood to the ductwork. Use duct tape to make all joints secure and air tight.

3.Align hood-mounting bracket to the two screws on the wall and hook hood into place. Tighten screws to secure hood to the wall. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING.

Duct Cover Installation

4.Mark the position of the duct cover-mounting bracket. Use calculation E from Table 2 for references. Attach and secure duct cover-mounting bracket with two screws (not provided). Refer to Figure 27. NOTE: Inner duct cover will cover the mounting bracket.

5.Connect electrical wires. Refer to “Wiring to Power Supply” on page 16.

6.Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood. Refer to Figure 28.