Fixed thresholding ATP disabled

When Adaptive Thresholding is selected, Contrast values may range from 1 to 100. A Contrast value of 100 is considered fully adaptive thresholding.

Fixed thresholding ATP disabled

ATP enabled

Dithering a method used to simulate gray levels. When selected, the Dithering options are available.

64-Level Bayer Dither, 64-Level 45 Degree Clustered Dot Screen and 64-Level Dispersed Dot Screen: these represent alternative screening options to emulate gray.

Color Correction the selection of a color table effects how the scanner reproduces the color of a scanned document. You can choose from the three Kodak default color tables: Pictures, Text and Text with Pictures, or if you have created your own custom color tables using the Brightness and Contrast Control, these tables will also be available.