11. Click on Print Test Form button. A progress bar appears as the form prints:

12. When the form printing is complete:

Go to Scanner for scanner calibration.

Go to Spectrocam for Spectrocam calibration.

Scanner

1.Place the calibration form on the platen of the DocuColor 12 and click Calibrate.

2.If the calibration is successful, the screen display says, "The calibration process was successful. You may now calibrate another media."

3.Click OK to go back to the calibration window.

Note: If the calibration process fails, check to make sure the test page is properly positioned on the platen. The scanable area is 11"x 17". If the calibration test form is outside this area, calibration will fail.

Spectrocam

1.Place the test form and ruler on the black scanner plate and position the measurement device on the first patch on the upper, left corner.

2.Click on the Calibrate button.

If the Spectrocam was not previously calibrated, a prompt directs you to measure/remeasure the white reference. Place the measurement device on the white target reference and touch the green sensor. After remeasuring the white reference, reposition the measurement device on the first patch on the upper