24" (610 mm) Max. Distance Between Blower and Outlet

Bond in accordance with applicable codes.

Install a GFCI-protected

120 V, 15 A grounded outlet.

Air Intake

3. Make the Electrical Connections – USA

WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the following procedures.

WARNING: Risk of electric shock. Connect the blower motor to a properly grounded, grounding-type receptacle protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not remove the grounding pin from the plug. Do not use a grounding adapter.

NOTICE: The blower motor is equipped with a cord and plug. A qualified electrician must install a GFCI- or RCD-protected, 120 V, 15 A, grounded outlet for the blower. No other load should be on this circuit.

Install an electrical outlet behind the bath, at least 1-1/2″ (38 mm) above the subfloor, and within reach of the 24″ (610 mm) power cord.

Plug the blower into this outlet.