Troubleshooting (cont.) |
|
| ||
|
|
|
| |
Symptoms | Probable | Recommended Action |
| |
|
| Causes |
|
|
|
| K. Solenoid is | K. Order a new solenoid service | |
|
| not working. | kit. |
|
2. | Low flow. | A. Filter is | A. Clean or replace the filter. | |
|
| plugged. |
|
|
|
| B. Supply | B. Check incoming water pressure. | |
|
| pressure is | Pressure should be at least 20 psi | |
|
| low. | (137 kPa). |
|
|
| C. Aerator is | C. Remove the aerator and clean it. | |
|
| plugged. | For calcium/mineral deposits, soak | |
|
|
| the aerator plastic insert in a 50:50 | |
|
|
| mixture of vinegar and water. Soak | |
|
|
| only the insert and no other | |
|
|
| components. |
|
3. | Constant | A. Filter is | A. Clean or replace the filter. | |
| water flow. | plugged. |
|
|
|
| B. Diaphragm | B. If the diaphragm is cut or torn, | |
|
| seal is | order a new diaphragm assembly. | |
|
| damaged or | Clean or replace the diaphragm. | |
|
| dirty. |
|
|
|
| C. Solenoid is | C. Order and install a new solenoid | |
|
| not working. | assembly. |
|
4. | Sporadic | A. The faucet | A. Verify that the faucet is mounted | |
| water flow. | is angled | according to the installation | |
|
| incorrectly to | directions. Ensure that the faucet is | |
|
| deck or | installed in a position that is above | |
|
| misaligned | the rim of the sink. |
|
|
| with user area. |
|
|
|
| B. The wires | B. Remove the spout and verify | |
|
| are pinched or | that the wires are tucked inside the | |
|
| damaged. | spout before reassembling. |
|
5. | Sensor | A. Low | A. Replace the power supply. | |
| flashes once | voltage. |
|
|
| approximately |
|
|
|
| every 2 |
|
|
|
| seconds. The |
|
|
|
| product |
|
|
|
| continues to |
|
|
|
| operate. |
|
|
|
|
|
|
| |
|
|
|
| |
| 12 | Kohler Co. |