*Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome. This will void the warranty.

Troubleshooting

Symptoms

Probable

Recommended Action

 

Causes

 

1. No water

A. Filter is

A. Clean or replace the filter.

flow.

plugged.

 

 

B. Sensor eyes

B. Wipe the sensor eyes with a

 

are dirty.

damp soft cloth. Wipe dry with a

 

 

dry soft cloth.

 

C. Water not

C. Verify that the water supply is

 

turned on.

turned on and that pressure is at

 

 

least 20 psi (137 kPa).

 

D. Incorrect

D. Verify that the faucet is mounted

 

installation.

as instructed in the installation

 

 

guide. Ensure that the sensor eyes

 

 

are above the rim of the sink. Refer

 

 

to the installation instructions.

 

E. The aerator

E. Remove and clean the aerator.

 

is plugged.

For calcium/mineral deposits, soak

 

 

the plastic insert in a 50:50 mix of

 

 

water and vinegar. Soak only the

 

 

plastic insert.

 

F. Sensor eyes

F. Replace the sensor assembly.

 

are scratched.

 

 

G. A flex hose

G. Check the flex hoses to make

 

is kinked.

certain they are not kinked. If a

 

 

flex hose is kinked, disconnect it,

 

 

straighten, and reconnect.

 

H. Power was

H. Wait 2 minutes after power is

 

interrupted.

restored as the sensor cycles

 

 

through the automatic sensing

 

 

distance.

 

I. Battery life

I. Replace the power supply.

 

expired.

 

 

J. Bleed hole

J. Clean or replace the diaphragm.

 

in diaphragm

 

 

is plugged or

 

 

debris exists

 

 

on the seal.

 

 

 

 