Warranty (cont.)
*Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome. This will void the warranty.
Troubleshooting
Symptoms | Probable | Recommended Action |
| Causes |
|
1. No water | A. Filter is | A. Clean or replace the filter. |
flow. | plugged. |
|
| B. Sensor eyes | B. Wipe the sensor eyes with a |
| are dirty. | damp soft cloth. Wipe dry with a |
|
| dry soft cloth. |
| C. Water not | C. Verify that the water supply is |
| turned on. | turned on and that pressure is at |
|
| least 20 psi (137 kPa). |
| D. Incorrect | D. Verify that the faucet is mounted |
| installation. | as instructed in the installation |
|
| guide. Ensure that the sensor eyes |
|
| are above the rim of the sink. Refer |
|
| to the installation instructions. |
| E. The aerator | E. Remove and clean the aerator. |
| is plugged. | For calcium/mineral deposits, soak |
|
| the plastic insert in a 50:50 mix of |
|
| water and vinegar. Soak only the |
|
| plastic insert. |
| F. Sensor eyes | F. Replace the sensor assembly. |
| are scratched. |
|
| G. A flex hose | G. Check the flex hoses to make |
| is kinked. | certain they are not kinked. If a |
|
| flex hose is kinked, disconnect it, |
|
| straighten, and reconnect. |
| H. Power was | H. Wait 2 minutes after power is |
| interrupted. | restored as the sensor cycles |
|
| through the automatic sensing |
|
| distance. |
| I. Battery life | I. Replace the power supply. |
| expired. |
|
| J. Bleed hole | J. Clean or replace the diaphragm. |
| in diaphragm |
|
| is plugged or |
|
| debris exists |
|
| on the seal. |
|
|
|
|
Kohler Co. | 11 |