Optional Temperature Limiting Adjustment

Handle

Screw

Spring

Washer Vandal-Resistant

Plug Button

Optional Temperature Limiting Adjustment

CAUTION: Risk of personal injury. Scalding may result if the temperature limit is not properly set.

NOTE: The water temperature does not need to be adjusted if the water temperature is below 105°F (41°C).

NOTE: Use a thermometer rated for 120°F (49°C) or greater.

NOTE: When using a tempered water supply, install the vandal-resistant plug button.

Adjust the Water Temperature Limit – Handle Installations

Turn on the water and adjust to full hot by turning the handle toward the back of the faucet until it stops.

Determine the temperature using a thermometer. If the temperature exceeds 105°F (41°C), complete the following steps.

NOTICE: Do not rotate the handle when removing the screw.

Using the 2.5 mm hex wrench provided, remove and retain the handle screw.

Remove and retain the handle with the spring washer.

Kohler Co.