ROUGH-IN PLUMBING

ROUGH-IN PLUMBING

Turn off the main water supply.

Install or relocate the supplies and outlets as necessary to conform to roughing-in dimensions. See Fig. #3 . For supply stop location, See Fig. #4 .

CAUTION: Risk of trap seal loss in

CAUTION: Risk of trap seal loss in back-to-back installations. See Fig. #2 . To prevent possible trap seal loss, the back-to-back Pressure Lite toilet should be connected to a vertical stack using one of the following three fittings:

SDouble fixture fitting

SDouble combination wye and 1/8 bends

SDouble wye and 1/8 bends

Double

Double

Double Wye

Fixture

Combination

and 1/8

Fitting

Wye and 1/8

Bends

 

Bends

 

 

Fig. #2

 

ROUGHING-IN DIMENSIONS

3/4º

3-1/16º

116

30-1/2º

19-3/8º

FRONT OF BOWL

 

2-3/4º

 

 

 

16-1/4º

 

19-1/4º

 

 

14-3/4º

 

 

2-5/8º

4-5/8º

 

 

12º

C

 

10º

L OF OUTLET

3/8º I.P.S. SUPPLY

7-3/4º

 

 

 

Fig. #3

INSTALL SUPPLY STOP

For supply installation, refer to the instructions packed with the supply stop.

Locate the supply stop so it is 2-5/8º above the floor line, and 7-3/4º to the left of the centerline of the closet flange.

2-5/8º

12º

Supply Stop

7-3/4º

 

 

Fig. #4

 

 

 