Replacing the Pump (cont.)
Remove the lower rim hose clamp by sliding the clamping heads apart.
Work the rim hose off the pump.
NOTE: The flow restrictor slip fits into the rim opening in the pump and is held in place by the rim hose. When the hose is removed from the pump, the restrictor may remain in the hose or on the pump. Save the restrictor for reuse.
Use
Inspect the lower rim hose for any damage. Replace if necessary.
Inspect the upper jet hose for any damage. Replace if necessary.
Install the Pump
Perform the following steps in order to install a new pump:
NOTE: The flow restrictor slip fits into the rim opening in the pump, and is held in place by the rim hose.
Use
Position the lower rim hose clamp on the rim hose.
Install the low rim hose on the pump.
Install the rim hose clamp by sliding the clamping heads together.
Position the upper jet hose clamp on the jet hose.
Position the pump in the tank and align it with the hose connections.
Push the lower rim supply hose into the vitreous china hole.
Install the upper jet hose onto the pump.
Install the upper hose clamp by sliding the clamping heads together.
Plug the modular plug and cord into the back of the flush button.
Plug the electrical cord for the toilet into the outlet.
NOTE: Use the proper termination devices as required by any local electrical codes.
Turn on the water.
Observe that the tank refills.