Symptom

Power

Heater

Probable Cause

Possible Remedy

 

Light

Setting

 

 

 

Low/Medium/

 

 

 

 

 

 

 

 

High

 

 

 

 

 

 

 

Low or No

ON

Any

Water supply pipework or

Flush supply pipe. Clean Inlet

flow

 

 

inlet filter restricted by a

Filter.

 

 

 

blockage or partial blockage.

 

 

ON

Any

Insufficient water supply

Contact local water company.

 

 

 

pressure/flow for operation.

Supply pressure must be a

 

 

 

 

minimum of 0.7 bar.

 

 

 

 

Note: If other appliances are

 

 

 

 

operating, pressure may drop

 

 

 

 

below 0.7 bar.

 

ON

Any

Other outlets (e.g. toilet,

Turn off other appliances whilst

 

 

 

garden hose, washing

shower is in use.

 

 

 

machine, etc.) drawing

 

 

 

 

water while the shower is

 

 

 

 

being used.

 

 

ON

Any

Handset blocked.

Remove and clean.

 

ON

Any

Cover not fitted correctly

Check Cover is cut and fitted

 

 

 

causing Start/Stop

correctly. Check services

 

 

 

button not to operate.

(electrical or plumbing) are not

 

 

 

 

interfering with location of Cover.

 

ON

Any

Inlet Valve faulty.

Replace.

 

ON

Any

Heater Tank excessively

Replace. In hard water areas

 

 

 

scaled.

consider the use of a water

 

 

 

 

softener.

 

 

 

 

 

Operation of

ON

II/III

Handset or Inlet Filter

Remove and clean.

Temperature

 

 

blocked.

 

Control has

ON

II/III

Inlet Valve faulty.

Replace.

little or no

effect on water

ON

II/III

Heater Tank failure.

Replace.

temperature.

 

 

 

 

 

ON

II/III

Microswitch failure.

Replace.

 

 

 

 

 