21
Owner’s Manual
Volume message filter
You can prevent the internal sound engine from receiving volume change messages.
If the Volume message filter is set to “On”, the K61P’s internal sound generator will
accept volume(07) message from Knob1, Knob2 and the Slider if they are assigned
control change cc#07.
If it’s set to “Off”, the K61P’s internal sound generator will reject volume(07) message
from Knob1, Knob2 and the Slider even if they are assigned control change cc#07.
1Hold down [BANK] button until the K-Series enters the Setting mode.
2Press the Program 8 [HARPSI 2/CHOIR/STRINGS 2] button (the button will flash).
C8C7C6C5C4C3C2C1
3Press note C4(On) or C#4(Off) to select the setting.
CC#07 flow chart

ON OFF

SG
Controller
K61P
Controller
K61P
SG
Computer Computer
* SG: Sound Generator
SG's volume knob controls
SG's volume level.
4Press [BANK] key to quit setting mode.