Image 17
8 Communication Protocol

8 Communication Protocol

The FC-42is compatible with the protocol (ver 1.2) described below. For RS-232, a null-modem connection between the FC-42and controller is used. The default data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit. All the values shown are hexadecimal.

 

Instruction

 

 

 

Byte 1

 

 

Byte 2

 

 

 

Byte 3

 

 

Byte 4

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

 

00

 

80

 

 

80

 

98+Machine

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLY TO

 

 

40

 

80

 

 

80

 

98+Machine

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ LOCAL

 

 

20

 

80+Parameter

 

 

80

 

B8+Machine

 

 

 

 

 

PARAMETER

 

 

 

 

 

Number

 

 

 

 

 

Addr

 

 

 

 

 

REPLY TO READ

 

 

60

 

80+Parameter

 

 

80+Parameter

 

B8+Machine

 

 

 

 

 

LOCAL

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

PARAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE LOCAL

 

 

21

 

80+Parameter

 

 

80+Parameter

 

B8+Machine

 

 

 

 

 

PARAMETER

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLY TO

 

 

61

 

80+Parameter

 

 

80+Parameter

 

B8+Machine

 

 

1

 

WRITE LOCAL

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

PARAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ GLOBAL

 

 

20

 

80+Parameter

 

 

80

 

98+Machine

 

 

 

 

 

PARAMETER

 

 

 

 

 

Number

 

 

 

 

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLY TO READ

 

 

60

 

80+Parameter

 

 

80+Parameter

 

98+Machine

 

 

 

 

 

GLOBAL

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

PARAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE GLOBAL

 

 

21

 

80+Parameter

 

 

80+Parameter

 

98+Machine

 

 

 

 

 

PARAMETER

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REPLY TO

 

 

61

 

80+Parameter

 

 

80+Parameter

 

98+Machine

 

 

1

 

WRITE GLOBAL

 

 

 

 

 

Number

 

 

Data

 

Addr

 

 

 

 

 

PARAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAVE

 

 

23

 

80 + Initial

 

 

80+Destination

 

98+Machine

 

 

2

 

 

 

 

 

 

 

 

Setup

 

 

Setup Number

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDENTIFY

 

 

3D

 

81

 

 

80

 

98+Machine

 

 

3

 

MACHINE

 

 

 

 

 

 

 

 

 

 

 

 

Addr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDENTIFY

 

 

3D

 

83

 

 

80

 

98+Machine

 

 

4

 

FIRMWARE

 

 

 

 

 

 

 

 

 

 

 

 

Addr

 

 

 

 

 

VERS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

FC-42 - Communication Protocol

 

 