5.3 Connecting the REMOTE Connector

Using the VP-411DS 4x1 Automatic UXGA / Audio Switcher

5.3 Connecting the REMOTE Connector

The contact closure remote control pins operate in a similar way to the Input selector button. Using the contact closure remote control you can select the UXGA input or cut off the inputs. To do so, temporarily connect the required input1 pin on the REMOTE terminal block connector to the GND (Ground) pin, as Figure 5 illustrates.

DO NOT connect more than one PIN to the GND PIN at the same time

To select IN 1, connect the 1 PIN to the G PIN

To select IN 2, connect the 2 PIN to the G PIN

To select IN 3, connect the 3 PIN to the G PIN

To select IN 4, connect the 4 PIN to the G PIN

To select OFF, connect the OFF PIN to the G PIN

Figure 5: Connecting the Contact Closure Remote Control PINs

1 IN1, IN 2, IN 3 IN 4, or OFF