34 VP-81K - Kramer Protocol
Identification Commands
Command Syntax Response
Read device serial number SN? SN SERIAL_NUMBER
Read device firmware
version VERSION? VERSION MAJOR .MINOR .BUILD .REVISION
Set machine name NAME MACHINE_NAME NAME MACHINE_NAME RESULT
Read machine name NA ME? NAME MACHINE_NAME
Reset machine name to
factory default* NAME-RST NAME-RST MACHINE_FACTORY_NAME
RESULT
*Note: machine name not equal to model name. This name relevance for site viewer identification of specific
machine or for network using (with DNS feature on).
MACHINE_NAME = Up to 14 Alfa-Numeric chars.
* Machine factory name = Model name + last 4 digits from serial number.
Set machine id number MACH-NUM
MACHINE_NUMBER MACH-NUM OLD_MACHINE_NUMBER
,NEW_MACHINE_NUMBER RESULT
* Response will send after machine number has been changed. So the replay with header will be:
NEW_MACHINE_NUMBER @MACH-NUM OLD_MACHINE_NUMBER ,NEW_MACHINE_NUMBER OK
Network Setting Commands
Set IP Address NET-IP IP_ADDRESS
NTIP NET-IP IP_ADDRESS RESULT
Read IP Address NET-IP?
NTIP? NET-IP IP_ADDRESS
Read MAC Address NET-MAC?
NTMC NET-MAC MAC_ADDRESS
Set subnet mask NET-MASK SUBNET_MASK
NTMSK NET-MASK SUBNET_MASK RESULT
Read subnet mask NET-MASK?
NTMSK? NET-MASK SUBNET_MASK
Set gateway address NET-GATE GATEWAY_ADDRESS
NTGT NET-GATE GATEWAY_ADDRESS RESULT
Read subnet mask NET-GATE?
NTGT? NET-GATE GATEWAY_ADDRESS
Set DHCP mode NET-DHCP DHCP_MODE
NTDH NET-DHCP DHCP_MODE RESULT
Read subnet mask NET-DHCP?
NTDH? NET-DHCP DHCP_MODE
DHCP_MODE =
0 – Don't use DHCP (Use IP set by factory or IP set command).
1 – Try to use DHCP, if unavailable use IP as above.
Change protocol
Ethernet port ETH-PORT PROTOCOL , PORT
ETHP ETH-PORT PROTOCOL ,PORT RESULT
Read protocol Ethernet
port ETH-PORT? PROTOCOL
ETHP? ETH-PORT PROTOCOL , PORT
PROTOCOL = TCP / UDP (transport layer protocol)
PORT = Ethernet port to enter protocol 3000 commands
1-65535 = User defined port
0 - reset port to factory default (50000 for UDP, 5000 for TCP)