12 VP-81K - Connecting the VP-81K
5.3 Connecting a PC or Controller to the RS-485 Port
You can operate the VP-81K via the RS-485 port from a distance of up to 1200m
(3900ft) using any device equipped with an RS-485 port (for example, a PC). For
successful communication, you must set the RS-485 machine number and bus
termination.
To connect a device with a RS-485 port to the VP-81K:
Connect the A (+) pin on the RS-485 port of the PC to the A (+) pin on the
RS-485 port on the rear panel of the VP-81K
Connect the B (–) pin on the RS-485 port of the PC to the B (–) pin on the
RS-485 port on the rear panel of the VP-81K
Connect the G pin on the RS-485 port of the PC to the G pin on the RS-485
port on the rear panel of the VP-81K
5.4 Controlling the VP-81K via the Ethernet Port
You can connect the VP-81K via the Ethernet in the following ways:
For direct connection to the PC, use a crossover cable (see Section 5.4.1)
For connection via a network hub or network router, use a straight-through
cable (see Section 5.4.2)

5.4.1 Connecting the Ethernet Port Directly to a PC (Crossover

Cable)

You can connect the Ethernet port of the VP-81K to the Ethernet port on your PC,
via a crossover cable with RJ-45 connectors.

This type of connection is recommended for identifying the VP-81K

with the factory configured default IP address

After connecting the Ethernet port, configure your PC as follows:
1. Right-click the My Network Places icon on your desktop.
2. Select Properties.