INSTALLATION
6) ROOM VENTILATION
To ensure correct operati on of the appliance, it is
important to ensure that the room where the hot
plate is installed has sufficient ventilation.
7) GAS CONNECTION
Natural Gas and Propane Gas
Natural Gas installations require the connection of
a gas regulator at the appliance. This regulator is
supplied with the appliance on purchase.
Ass embl e t he regul ator (n otin g t he gas flo w
direction) and transition pieces (supplied with the
appliance), in accordance with below figure.
The trans ition piece on the suppl y sid e of the
regulator must be provided by the installer.
Unions compati ble with the hose fittings must be
used and connections tested for gas leaks.
Ensure the supply connection point is accessible
with the appliance installed.
War ning : ensu re tha t the ho se ass embl y is
restrained from accidental contact with the flue or
flue outlet of an underbench oven.