Electrical connection
■The
■Both legal wiring regulations and the requirements of your local electricity supply board must be fully complied with.
■When connecting the hob, a device must be provided which enables all- pole disconnection of the hob from the supply with a gap construction of at least 3 mm. Circuit breakers, fuses and contactors are considered to be suitable disconnecting units.
■When connecting and repairing the appliance disconnect it from the elec- tricity supply with one of these devices.
■Overall protection against electric shock must be ensured by the installation.
■The earthed conductor lead must be sufficiently long so that, in the event of failure of the strain relief, it is not subjected to strain until after the live wires of the connection cable.
■Any superfluous cable must be removed from the installation area beneath the appliance.
At the factory the electronic hob has been equipped with a
The connecting box is fastened to the kitchen wall behind the
■When assembling the connecting box remember that it must be at least 300 mm from the floor, as shown in the drawing.
■The connecting box must not come into contact with any hot appliance parts.
■The connecting box must not be used as a voltage distributor for other appliances.
■The appliance is connected to the mains at the connecting box as shown in the wiring diagram. The connection may only be made in the connector box.
■The connector box must not be removed.
■The fitted connection cable must be replaced by the KÜPPERSBUSCH Cu- stomer Service if it becomes damaged.
■The
Connection diagram:
Electrical | Permanent connection by means of an oven connection | ||
connection | socket. |
| |
Connection | is depicted on the underside of the appliance, suitable for | ||
diagram | the various types of mains. | ||
Connection data | Permanent connection 400 V 3 N ~ 50 Hz | ||
| (AC 230 V in UK) | ||
| Voltage of heating element: 230 V | ||
| Total connection output: 10.4 kW | ||
| 400 | V 3 N ~ safety current 16 A | |
| 400 | V 2 | N ~ safety current 20 A |
| 230 | V 1 | N ~ safety current 25 A |
| 230 | V 3 | ~ safety current 16 A |
Connection cable | Use H 05 |
[When assembling the connecting box remember that it must be at least 300 mm from the floor, as shown in the drawing.
Cable to the hob
Supply line from cooker junktion box
The conductor colours may be different. The connection diagram and the terminal numbers are the decisive factors.
base
Three-phase system 230 V phase against phase
[Caution: Incorrect connection results in the total destruction of the power electronics.
24 | KGCT 907.2E |