SET TEMPERATURE
The followings programs compose this menu:
SET BOILER TEMPERATURE
TIME OVERHEATING BOILER
After this time of “machine stopped” the boiler is overheated.
SET OVERHEATING BOILER
Value of overheating of the boiler (max. 5°C).
TIME FILLING UP BOILER
Every “minute set” the pump refills the boiler to keep the maximum level.
SET FILLING UP BOILER
Duration of refilling for boiler.
OPTIONS
This menu is constituted by 2 different levels each of which is protected from a password:
1st level. Operator - devoted to the operator of the machine
2nd level. Manager - devoted to the technician / manager of the machine
The machine has 3 types of operation each of which it has a counter of selections and amounts:
normal: | normal working with selection priced |
test : | working with selections priced but with the money does- |
| n’t go into the coin box (example: the technician has to |
| test the machine and the payment system). |
Free test: | working with free selections. |
The counters of each level are independent one with the other, therefore the zero resetting of the counters of a level doesn't influence the counters of the other level.
EVENTS
In this menu it is possible to notice the last 100 events of the machine. Entering the menu with ENTER the following data will be visualized:
Id: XX | RESULT P:n |
ID indicates the kind of event, that can be a code drink or an internal operation of the machine (see chart).
RESULT indicates if the event has been finished good (GOOD) or an error is oc- curred (Ennn) where nnn corresponds to a number that the type of error represents (see chart).
POS indicates the position of the event (from 1 to 100). To scroll the various events use the keys “+” and “
Internal operation codes
94 espresso group positioning
96 filter counter reached
97 boiler refilling
99washing
Errors codes
E103 | espresso group positioning in “normal position ” |
E104 | espresso group positioning in “supply position ” |
E105 | espresso supplying |
E106 | soluble supplying |
E107 | coffee grinding |
E112 | lack of water |
E113 | boiler temperature |
E115 | coffee pucks counter |
E118 | initial heating |
Pag. 14 | Pag. 11 |