Error | Cause | Remedy |
Error | Hardware error | Switch on/off the device several |
|
| times. If the symbol still appears, |
|
| then your instrument is defec- |
|
| tive. Please call your dealer for |
|
| assistance. |
Technical data
Distance measurements: |
| |
Measuring accuracy up to 10 m (2 σ) | typically: ± 1.0 mm* | |
Power Range Technology™: | 0.05 m to 200 m | |
Range (use target plate from about 100 m) | ||
| ||
Smallest unit displayed | 0.1 mm | |
Distance measurement | 9 | |
Minimum/maximum measurement, Conti- | 9 | |
nuous measurement | ||
| ||
Area/volume calculation of room data | 9 | |
Addition / subtraction | 9 | |
Indirect measurement using Pythagoras | 9 | |
Trapezium measurement | 9 | |
Tilt measurements: |
| |
Tilt sensor: |
| |
Accuracy (2 σ) |
| |
- to laser beam | - 0.1° / +0.2° ** | |
- to the housing | ± 0.1° ** | |
Indirect measurement using tilt sensor | 9 | |
(direct horizontal distance) | ||
| ||
Angle measurement using tilt sensor | 9 | |
(360°) | ||
| ||
General: |
| |
Laser class | II | |
Laser type | 635 nm, < 1 mW | |
Ø laser point | 6 / 30 / 60 mm | |
(at distances) | (10 / 50 / 100 m) | |
Autom. laser | after 3 min |
Autom. instrument | after 6 min |
| |
Display illumination | 9 | GB | |
Multifunctional endpiece | 9 | ||
| |||
Timer | 9 |
| |
Save constant value | 9 |
| |
Historical storage | 30 values |
| |
BLUETOOTH® 2.0 | QD ID B014433 |
| |
Range of BLUETOOTH® Cl. 2 | 10 m |
| |
Tripod thread (Type: | 9 |
| |
Battery life, | up to |
| |
Type AA, 2 x 1.5V | 5 000 measurements |
| |
Protection against splashes and dust | IP 54, |
| |
|
| ||
Dimensions | 143.5 x 55 x 30 mm |
| |
Weight (with batteries) | 195 g |
| |
Temperature range: |
|
| |
Storage |
| ||
|
| ||
Operation |
|
| |
| (14°F up to +122°F) |
|
*maximum deviation occurs under unfavourable conditions such as bright sunlight or when measuring to poorly reflecting or very rough surfaces. Measuring accuracy between 10 m and 30 m may deteriorate to approx. ± 0.025 mm/m, for distances above 30 m to ± 0.1 mm/m. In long range mode the maximum deviation from a distance of 30 m increases to +/- 0.15 mm/m.
**applies at room temperature. For the whole operating temperature range the maximum deviation increases by +/- 0.1°.
Measuring conditions
Measuring range
The range is limited to 200 m.
At night or dusk and if the target is in shadow the measuring range without target plate is increased. Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.
Leica DISTO™ D8 LCA782205a gb