Leica 764558, 764555 manual Offset, Digital pointfinder image black / white, Level in status field

Models: 764555 764558

1 24
Download 24 pages 64 b
Page 11
Image 11

GB

Offset ()

An offset adds or subtracts a specified value automatically to or from all measurements. This function allows tolerances to be taken into account (e.g. unfinished dimensions compared with finished dimensions). If you selected the Offset function in the menu, you can now adjust the value

using the or the key. Pressing the key for longer increases the rate of change of the values. When you reach the desired offset value,

confirm it with the key. The display shows the appropriate symbol

or for as long as the offset value is set.

1Carry out a first measurement on a level surface. The device

confirms the measurement with .

2Rotate the device horizontally through 180° .

3Press the key and confirm that the device was rotated through 180°.

4Press the key and take the second measurement. The device

confirms the measurement with .

The tilt sensor is calibrated.

Digital pointfinder image black / white ()

The display in pointfinder mode can be changed to black / white.

Level in status field ( )

The Level (in °) in status field can be switched on or off.

Reset - returning the instrument to the factory settings ()

The instrument has a Reset function. If you select the menu function Reset and confirm, the device returns to the factory settings and stack and memory are deleted.

)All customised settings and stored values are also lost.

Calibrate the tilt sensor ()

You can calibrate the tilt sensor in the device. Calibration requires two measurements on a level surface.

Select calibration mode in the menu .

Menu functions

8

Leica DISTO™ D8 LCA782205a gb

Page 11
Image 11
Leica 764558, 764555 Offset, Digital pointfinder image black / white, Level in status field, Calibrate the tilt sensor