Press the key briefly to enter the submenu of the selected main menu item.

By pressing the or keys you can make the alterations in the submenu.

Press and hold the key to accept the settings.

Pressing the button for longer in the menu allows you to quit the settings function without saving.

Setting the unit for distance measurements

The following units can be set:

 

Distance

Area

Volume

1.1

0.0000 m

0.000 m²

0.000 m³

1.2

0.000 m

0.000 m²

0.000 m³

 

 

 

 

1.3

0.00 m

0.000 m²

0.000 m³

 

 

 

 

1.4

0.00 ft

0.00 ft²

0.00 ft³

1.5

0'00'' 1/

0.00 ft²

0.00 ft³

 

32

 

 

1.6

0.0 in

0.00 ft²

0.00 ft³

 

 

 

 

1.7

0 1/32 in

0.00 ft²

0.00 ft³

1.8

0.000 yd

0.000 yd²

0.000 yd³

 

 

 

 

Setting the unit for tilt measurements

The following units can be set for tilt measurements:

Units for tilt

2.1± 90.0°

2.2± 180.0°

2.3360.0°

2.40.00 %

2.50.0 mm/m

2.60.00 in/ft

Display illumination (

)

 

The brightness of the display has six levels of adjustment. Step 6 is the

GB

brightest and step 1 is the darkest setting.

 

Long range Mode ()

Unfavourable conditions (strong sunlight or a very weak reflective target surface) may reduce the range of the device, in spite of this the long range mode allows you to take measurements over longer distances. The use of

a tripod and measurement initiation by pressing the key are recom- mended when measurements over 30m are made over longer time periods in these conditions. (For details see Technical specifications)

)The settings are reset when the device is switched off.

Measuring with the tripod ()

The reference point may be adjusted to the tripod mount if the user requires a measurement from the actual mounting grommit versus the

front or back of the DISTO™. To do this select the symbol in this menu item. You can switch the reference on the tripod on or off. The

setting can be seen on the display

.

)We recommend that measurements are initiated using the key when using the device on a tripod in order to prevent loss of sharpness.

)The settings are reset when the device is switched off.

Beep ( )

You can switch the beep on or off.

Leica DISTO™ D8 LCA782205a gb