![](/images/new-backgrounds/1209371/20937131x1.webp)
EN |
remote for this adjustment will make the job easier by not disturbing the laser.
After completing the changes to the
XPress the Minus key
XPress the On/Off key
Use of the remote for this adjustment will make the job easier by not disturbing the laser.
After completing the changes to the
XPress the Minus key
XPress the On/Off key
Adjusting vertical accuracy – The Z-axis
After checking the vertical accuracy of your laser, perform the following steps to adjust the
XTurn off the laser.
XPlace the laser in the laydown position approximately 6 meters (20 feet) from a plumb line on a wall.
XPress and hold the Auto/Manual key
XAfter the X and Y LED’s blink three times simultane- ously, release the Auto/Manual key.
•The
•The
•The head will not be rotating.
•To use a receiver, press the Scan/Rotation key
XPress a CCW/CW key
Check your work
After any accuracy adjustments always double check your work, by making a final check of the laser.
Check and Adjust
13
Roteo 20HV/25H/35/35G - 1.2.0en