Technical Data

Distance measurement

Typical Measuring Tolerance*

± 1.0 mm / ~1/16" ***

Maximum Measuring

± 2.0 mm / 0.08 in ***

Tolerance**

 

Typical Range*

200 m / 660 ft

Range at unfavourable

80 m / 260 ft

condition ****

 

Smallest unit displayed

0.1 mm / 1/32 in

Power Range Technology

yes

Ø laser point

6 /30 / 60 mm

at distances

(10 / 50 / 100 m)

Tilt measurement

Measuring tolerance to laser

-0.1° / +0.2°

beam*****

 

Measuring tolerance to

± 0.1°

housing*****

 

Range

360°

 

 

General

Laser class

2

Laser type

635 nm, < 1 mW

Protection class

IP54 (dust- and splash

 

water protected)

Autom. laser switch off

after 90 s

Autom. power switch-off

after 180 s

Bluethooth® Smart

Bluethooth v4.0

Range of Bluethooth®

<10 m

Dimension (H x D x W)

61 x 31 x 164 mm

 

2.4 x 1.2 x 6.5 in

Weight

238 g / 8.4 oz

Temperature range:

-25 to 60 °C

- Storage

- Operation

-13 to 140 °F

-10 to 50 °C

- Charging

14 to 122 °F

-10 to 40 °C

 

14 to 104 °F

Photos / Screenshots

Resolution for photos

800 x 600 dpi

Resolution for screenshots

240 x 400 dpi

File format

JPG

Download of gallery

USB

 

 

Battery (Li-Ion)

Rated voltage

3.7

V

Capacity

2.6

Ah

Measurements per battery

Approx. 4000

charge

 

 

Charging time

Approx. 4 h

Output voltage

5.0

V

 

 

 

Charging current

1 A

 

 

 

 

*applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC

**applies for 10 to 100 % target reflectivity, high background illumination, - 10 ºC to + 50 ºC

***Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between 30 m to 100 m and to 0.30 mm/m for distances above 100 m

****applies for 100 % target reflectivity, background illumi- nation of approximately 30'000 lux

*****after user calibration. Additional angle related devia- tion of +/- 0.01° per degree up to +/-45° in each quadrant.

Applies at room temperature. For the whole operating temperature range the maximum deviation increases by +/-0.1°.

EN

iAt a recommended storage tempera- ture of -20°C to +30°C (-4°F to

+86°F), batteries containing a 50% to 100% charge can be stored up to 1 year. After this storage period the batteries must be recharged.

iFor accurate indirect results, the use of a tripod is recommended. For accurate

tilt measurements a transverse tilt should be avoided.

Leica DISTOTM D810 touch 799093a

37

 

 

Page 38
Image 38
Leica DISTO D810, 806648 manual Technical Data, Tilt measurements a transverse tilt should be avoided