Technical Data
Distance measurement
Typical Measuring Tolerance* | ± 1.0 mm / ~1/16" *** |
Maximum Measuring | ± 2.0 mm / 0.08 in *** |
Tolerance** |
|
Typical Range* | 200 m / 660 ft |
Range at unfavourable | 80 m / 260 ft |
condition **** |
|
Smallest unit displayed | 0.1 mm / 1/32 in |
Power Range Technology™ | yes |
Ø laser point | 6 /30 / 60 mm |
at distances | (10 / 50 / 100 m) |
Tilt measurement
Measuring tolerance to laser | |
beam***** |
|
Measuring tolerance to | ± 0.1° |
housing***** |
|
Range | 360° |
|
|
General
Laser class | 2 |
Laser type | 635 nm, < 1 mW |
Protection class | IP54 (dust- and splash |
| water protected) |
Autom. laser switch off | after 90 s |
Autom. power | after 180 s |
Bluethooth® Smart | Bluethooth v4.0 |
Range of Bluethooth® | <10 m |
Dimension (H x D x W) | 61 x 31 x 164 mm |
| 2.4 x 1.2 x 6.5 in |
Weight | 238 g / 8.4 oz |
Temperature range: | |
- Storage | |
- Operation | |
- Charging | 14 to 122 °F |
| 14 to 104 °F |
Photos / Screenshots
Resolution for photos | 800 x 600 dpi |
Resolution for screenshots | 240 x 400 dpi |
File format | JPG |
Download of gallery | USB |
|
|
Battery (Li-Ion)
Rated voltage | 3.7 | V |
Capacity | 2.6 | Ah |
Measurements per battery | Approx. 4000 | |
charge |
|
|
Charging time | Approx. 4 h | |
Output voltage | 5.0 | V |
|
|
|
Charging current | 1 A |
|
|
|
|
*applies for 100 % target reflectivity (white painted wall), low background illumination, 25 ºC
**applies for 10 to 100 % target reflectivity, high background illumination, - 10 ºC to + 50 ºC
***Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between 30 m to 100 m and to 0.30 mm/m for distances above 100 m
****applies for 100 % target reflectivity, background illumi- nation of approximately 30'000 lux
*****after user calibration. Additional angle related devia- tion of +/- 0.01° per degree up to
Applies at room temperature. For the whole operating temperature range the maximum deviation increases by
EN
iAt a recommended storage tempera- ture of
+86°F), batteries containing a 50% to 100% charge can be stored up to 1 year. After this storage period the batteries must be recharged.
iFor accurate indirect results, the use of a tripod is recommended. For accurate
tilt measurements a transverse tilt should be avoided.
Leica DISTOTM D810 touch 799093a | 37 |
|
|