![HORIZONTAL VENT TERMINATION REQUIREMENTS](/images/new-backgrounds/44173/4417319x1.webp)
INSTALLATION - MODEL L20
HORIZONTAL VENT TERMINATION REQUIREMENTS
The venting terminals should not be recessed into a wall or siding.
A = | 2” | Clearances above grade, veranda, porch, deck or bal- | |
|
| cony. |
|
B = | 12” | Clearance to window or door that may be opened. | |
C = | 9” | (USA) Clearance to permanently closed window. | |
| 12” (CAN) |
| |
D = | 24” | Vertical clearance to ventilated soffit located above the | |
|
| terminal within a horizontal distance of 2 feet (60 cm) | |
|
| from the | |
E = | 12” | Clearance to unventilated soffit. | |
F = | 9” | Clearance to outside corner. | |
G = | 6” | Clearance to inside corner. | |
H = | 3 ft. (USA) | Not to be installed above a meter/regulator | |
|
| assembly within 3 feet (90 cm) horizontally from the | |
|
| centerline of the regulator. | |
I = | 3 ft. (USA) | Clearance to service regulator vent outlet. | |
| 6 ft.(CAN) |
|
J = 9” (USA) Clearance to
K = 3 ft. (USA) Clearance to a mechanical air supply inlet. 6 ft. (CAN)
L* = 7 ft. (USA) Clearance above paved
M**= 12” Clearance under veranda, porch, deck or balcony
*A vent shall not terminate directly above a
**Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor.
•Note: Local Codes or Regulations may require different clear- ances.
PAGE 10