![SPECIFICATIONS: Model L20 BF-2](/images/new-backgrounds/44173/4417353x1.webp)
SPECIFICATIONS: Model L20 BF-2
Flue Size | 4” - Top Vent |
Height Overall | 29” |
Height to Flue |
|
Outlet | 28 ¾” |
Width | 23” |
Depth | 15” |
Fuel | Natural Gas (standard) |
| (or) LP Gas (convertible). |
| Gas inlet 3/8” |
| (or) remove flex, 3/8” |
Performance | Variable Flame Control. |
Features | High Efficiency Heat Exchanger. |
| Natural Convection & Radiant Heat. |
| Standing Pilot / Operates During Power |
| Outages. Remote Control & Wall |
| Thermostat Capable. |
Technical | Honeywell Combination Gas Control |
Features | Valve, Millivolt - VS8520E. Safety Shut |
| Down Sensor (Spill Switch). |
| Pan Burner with Tuned Ports. |
| Radiant & Fan Assisted Convection |
| Heat. |
Safety Test | Tested and certified by CSA to ANSI standards. |
| |
| Gas Fireplace Heater |
Heat Input | 17,000 to 26,000 BTU’s (Nat. Gas) |
| 17,000 to 24,000 BTU’s (Propane) |
Ship Weight | 185 lb.’s |
Dimensions shown are approximations only (+ / - ¼”)
Top View
Side View
SPECIFICATIONS
GAS TYPE | NATURAL GAS | PROPANE (LP) | CLEARANCES TO COMBUSTIBLES |
|
| |
Orifice Size | #40 | Back Wall Min. | 2 In. / 51 mm | |||
Minimum Supply Pressure | 4.5” WC | 10.5” WC | Side Wall Min. | 12 | In. / 305 mm | |
Maximum Supply Pressure | 10.5” WC | 13.0” WC | Corner (45° angle)s |
|
| |
HIGH SETTING |
|
|
| stove corner to wall, min. | 2 In. / 51 mm | |
Manifold Pressure | 3.5” WC | 10.0” WC | Ceiling Height Minimum | 65 In. / 1651 mm | ||
Input BTU/HR | 26,000 | 24,000 |
| Alcove Min. Height | 65 | In. / 1651 mm |
LOW SETTING |
|
|
| Alcove Min. width | 47 | In. / 1194 mm |
Mainfold Pressure | 1.8” WC | 6.6” WC | Alcove - Max. Depth into |
|
| |
Input BTU / HR | 17,000 | 17,000 |
| stove face to alcove opening | 24 | In. / 610 mm |
|
|
|
|
|
| |
♦ Altitude - U.S.A. |
| * With the orifice, manifold pressure and input ratings shown | ||||
♦ Altitude - Canada |
| above. |
|
| ||
For installation higher than altitudes shown above, reorifice per Gas Codes. |
|
|
|
| ||
|
|
|
|
|
|
|
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must be field conversed using the LP Conversion Kit supplied with appliance.
PAGE 27