Lennox Hearth EN53-VDLE Troubleshooting the Electronic Ignition System, Symptom, Possible causes

Models: EN53-VDLE MN53-VDLE MN54-VDLE MP04-VDLE MP53-VDLE MN04-VDLE EN54-VDLE MP54-VDLE EN04-VDLE

1 20
Download 20 pages 12.93 Kb
Page 17
Image 17
Troubleshooting the Electronic Ignition System

Troubleshooting the Electronic Ignition System

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

 

Symptom

Possible causes

Corrective action

 

 

 

 

 

1.

Nothing happens when

A. Low voltage/or bad lead

Check voltage on AC terminals of module an/or batteries. The value should be

 

ON/OFF switch is turned

wires.

around 2.7 to 3.2 VAC. Confirm that wire connections are secure.

 

on (pilot does not spark).

 

 

 

 

 

B. Damaged igniter wire.

Check for visible cracked casing, cuts, etc.

 

 

 

 

 

 

 

 

 

 

 

C. Damaged pilot assembly.

Check pilot assembly for visibly broken spark electrode, etc.

 

 

 

 

 

 

 

 

D. Batteries Low

Check voltage on D.C. terminal of batteries. The value should be around 3.0V

 

 

 

 

2.

The main burner does

A. No fuel supply.

Ensure that the gas supply is turned on.

 

not light and the igniter

 

 

 

B. Loose sensor wire.

Ensure sensor wire connection is secure.

 

is sparking.

 

 

 

 

 

 

 

 

C. Lose wires to valve.

Ensure black, green and orange wires connection is secure to valve.

 

 

 

 

 

 

 

 

D. Loose wires to ignition

Ensure black sensor wire (S) and black igniter wire (I) is secure to ignition

 

 

 

module.

module.

 

 

 

 

 

 

 

 

E. Air in the gas line.

Purge gas line of air.

 

 

 

 

 

 

 

 

F. Low voltage.

Test voltage at AC terminals of module and/or batteries. It should be around

 

 

 

 

2.7 to 3.2 VAC.

 

 

 

 

3.

The main burner come

A. Gas supply is turned

Turned gas supply to "ON".

 

"ON" but then go "OFF".

"OFF".

 

 

 

 

 

 

 

 

 

B. Loose wire connection on

Check wire connection.

 

 

 

valve or ignition module.

 

 

 

 

 

 

 

 

 

C. Flame does not engulf

Check location of sensor.

 

 

 

flame sensor.

 

 

 

 

 

 

 

 

 

D. Obstructed vent system.

Check vent system for obstructions.

 

 

 

 

4.

The log and glass soot.

A. Flame impingement on

Check for proper log placement.

 

 

 

the log.

 

 

 

 

 

 

 

 

 

B. Improper air shutter

Check for proper air shutter openings.

 

 

 

opening.

 

 

 

 

 

 

17

Page 17
Image 17
Lennox Hearth EN53-VDLE manual Troubleshooting the Electronic Ignition System, Symptom, Possible causes, Corrective action