| Air | |
|
|
| Shutter | |
Venturi |
| Rod | ||
|
| |||
| Valve | Lever Arm | ||
| MAIN BURNER |
|
| |
FACTORY SHUTTER OPENING SETTING | ||||
Models | Natural Gas | Propane Gas | ||
inches (mm) | inches (mm) | |||
| ||||
ELDV35 | 1/8 (3.2) | 3/8 | (9.5) | |
ELDV40 | 1/4 (6.4) | 7/16 | (11.1) | |
ELDV45 | 1/4 (6.4) | 7/16 | (11.1) | |
Figure 5 |
|
|
|
Log Placement
Warning: Logs get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the ap- pliance before you install grate and logs.
Warning: This appliance is not meant to burn wood. Any attempt to do so could cause irreparable damage to your appliance and prove hazardous to your safety.
Warning: The size and position oF the log set was engineered to give your appliance a safe, reliable and attractive flame pattern. Any attempt to use a different log set in the fireplace will void the Warranty and will result in incomplete combustion, sooting, and poor flame quality.
Note: The log set and fire are artistically ar- ranged to provide a random asymmetric look to the fire. The fire intentionally does not burn in the left rear quarter of the log set.
Carefully position the ceramic fiber logs and twigs over the burner as shown in Figures 6 (ELDV35),
7 (ELDV40) or 8 (ELDV45) on this page.
These fires are designed to provide a rich orange/red glow on the logs. Placement of the rear log is critical and can be adjusted to taste. Refer to the detailed log placement instructions provided in the LOG PLACEMENT GUIDE accompanying this document.
Figure 6 | ELDV35 (With Optional Brick Liner Kit) |
|
|
Figure 7 | ELDV40 (With Optional Brick Liner Kit) |
|
|
Figure 8 | ELDV45 |
|
|
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. |
|