FLAME GENERATION BULBS

1.Hold the front glass panel, lift up and move backwards to take out the front glass panel (refer to Figure 6 ).

2.From the bottom, gently pull forward and lift up log/ember bed until front edge clears the front of the unit (do not pull up on logs).

3.Remove two screws on the top corners of the glass that hold glass in place (see Figure 9 ).

Figure 9

4.With gloves and safety glasses in place, use both hands to hold the bottom of the glass. Use fingers to gently push the glass towards you until the glass falls onto you hands. Gently hold the glass, using both hands, and place glass on smooth, soft surface to avoid breakage.

5.Remove screws and loosen and pull up and away the flame board (see Figure 10 ).

Screws

Figure 10

6.Locate flame generation cylindrical drum.

8

7.Squeeze half of the drum cylinder (see Figure 11 ) until its top edge clears the top drum track. Remove bottom edge of cylinder drum from the bottom drum track. This will give you access to the light bulbs.

Note: Do not exert excessive pressure on the drum cylinder as this may cause damage.

8.Remove spring clip (see Figure 12 ). Hold socket and pull out old bulb.

Figure 11

Spring Clip

 

Bulb

Figure 12

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

9.Hold socket and push in new bulb (DO NOT exceed wattage). Replace spring clip.

10.Replace steps 8 and 9 for second bulb.

11.Insert bottom edge of removed cylinder half into bottom drum track. Squeeze drum cylinder until its top edge fits into top drum track.

12.With gloves, carefully replace glass. Slide top of glass into metal slot and slide bottom onto ledge.

13.Place brackets against glass and tighten screws.

14.Gently push ember bed down until it rests inside its area.

15.Replace grate and screws.

WARNING: TURN OFF THE FIREPLACE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC FIREPLACE.

WARNING: THE FIREPLACE MUST BE UNPLUGGED/DISCONNECTED FROM THE POWER SUPPLY PRIOR TO ANY MAINTENANCE OR CLEANING IN ORDER TO REDUCE THE RISK ELECTRIC SHOCK OR FIRE.

WARNING: THE HALOGEN LIGHT BULBS IN YOUR FIREPLACE CAN BECOME EXTREMELY HOT. ALLOW AT LEAST 10 MINUTES BETWEEN TURNING OFF THE FIREPLACE AND REMOVING LIGHT BULBS TO AVOID THE ACCIDENTAL BURNING OF SKIN.

CAUTION: Do not exceed a 35 Watt bulb. Use of a higher rater bulb may result in a fire, causing prperty damage, personel injury or loss of life.

CAUTION: Do not touch the bulbs, oils from your skin will damage them when they heat up. Use gloves or cloth when handling bulbs.