Removingthe Bottom Panel
Remove the two screws that secure the bottom cap to the furnace. Pivot the bottom cap down to release the bottom panel. Once the bottom panel has been removed, reinstall the bottom cap, See figure 9.
Removing the Bottom Panel
Screw
\/
Bottom Cap
Bottom
FIGURE 9
Leveling an Upflow Unit
When the side return air inlets are used in an upflow ap- plication, it may be necessary to install leveling bolts on the bottom of the furnace. Use
NOTE - The maximum length of the bolt is
1 - Lie the furnace on its back and drill a 5/16 inch diame- ter hole in each corner of the furnace'sbottom. See fig- ure 10 for the correct location of the holes, Drill through the bottom panel and the bottom flange of the cabinet,
2 - Install one bolt and two nuts into each hole. Screw the first nut onto a bolt and then insert the bolt into a hole, A
fiat washer may be added between the nut and the bot- tom of the unit,
3 - Screw another nut onto the bolt on the inside of the fur-
nace base. A flat washer may be added between the nut and the bottom of the unit,
4 - Adjust the outside nut to the appropriate height and tighten the inside nut to secure the arrangement,
Leveling | Bolt Installation | |
| 3/8 | Inches (mm) |
|
| |
| (10) _r |
|
Furnace Front3/8 | _'1[ | |
|
| (44) |
|
| Leveling Bolt | |
(44) |
|
| |
|
| Furnace | Locations |
|
|
| |
|
| Bottom |
|
Leveling | Bolt |
| 3/8 |
| (10) | ||
Locati_ |
|
| |
|
|
|
3/81-3/4
(10)(44)
FIGURE 10
Horizontal Applications
The G50UH(X) furnace can be installed in horizontal ap- plications,
Allow for clearances to combustible materials as indicated on the unit nameplate, Minimum clearances for closet or al- cove installations are shown in figure 11,
Horizontal Application
Installation Clearances
Top
Left End |
|
|
| Right | End | ||
| Bottom |
|
|
|
| ||
Vent Connector | Type C | Type | B1 | ||||
Type | |||||||
|
|
|
|
|
| ||
Top |
| 0 |
|
| 0 |
| |
*Front | 3 in. | (76 | ram) | 3 in. | (76 | ram) | |
Back |
| 0 |
|
| 0 |
| |
Ends | 2 in. | (51 ram) | 2 in. | (51 | ram) | ||
Vent | 6 in. | (152 | ram) | 1 in. | (25 | ram) | |
Floor |
| o:_ |
| o:_ |
*Front clearance in alcove installation must be 24 in. (610 ram). Maintain a minimum of 24 in. (610 ram) for front service access. _:For installations on a combustible floor, do not install the furnace directly on carpeting, tile or other combustible materials other than wood flooring.
FIGURE 11