UNIT DIMENSIONS - INCHES (MM)

A

 

B

 

 

SIDE

 

 

VIEW

 

 

FIGURE 2

 

 

TABLE 1

 

 

UNIT DIMENSIONS

 

Model Numbers

A

B

13ACX-018-230

24-1/4 (616)

25-1/4 (641)

13ACX-024-230

24-1/4 (616)

25-1/4 (641)

13ACX-030-230

24-1/4 (616)

29-1/4 (743)

13ACX-036-230

24-1/4 (616)

29-1/4 (743)

13ACX-042-230

28-1/4 (718)

29-1/4 (743)

13ACX-048-230

28-1/4 (718)

33-1/4 (845)

13ACX-060-230

28-1/4 (718)

29-1/4 (743)

STEP 1 -- SETTING THE UNIT (CONTIN­ UED) -- Unit Placement

WARNING

To prevent personal injury, as well as damage to panels, unit or structure, observe the following:

While installing or servicing this unit, carefully stow all removed panels so that the panels will not cause injury to personnel, objects or nearby structures. Also, take care to store panels where they will not be subject to damage (e.g., being bent or scratched).

While handling or stowing the panels, consider any weather conditions (especially wind) that may cause panels to be blown around and damaged.

NOTICE !

Roof Damage!

This system contains both refrigerant and oil. Some rubber roofing material may absorb oil, causing the rubber to degrade. Failure to follow this notice could result in damage to roof surface.

IMPORTANT !

This model is designed for use in check / expansion valve systems only. An indoor expansion valve ap­ proved for use with HFC-410A refrigerant must be or­ dered separately and installed prior to operating the system.

IMPORTANT !

Exhaust vents from dryers, water heaters and furnaces should be directed away from the outdoor unit. Pro­ longed exposure to exhaust gases and the chemicals contained within them may cause condensation to form on the steel cabinet and other metal components of the outdoor unit. This will diminish unit performance and longevity.

PLACEMENT

INSTALL UNIT AWAY

FROM WINDOWS

TWO 90_ ELBOWS INSTALLED IN LINE SET

WILL REDUCE LINE SET VIBRATION

FIGURE 3

SLAB MOUNTING

Install unit level or, if on a slope, maintain slope tolerance of 2 degrees (or 2 inches per 5 feet [50 mm per 1.5 m]) away from building structure.

BUILDING

DISCHARGE AIR

STRUCTURE

 

MOUNTING

SLAB

GROUND LEVEL

FIGURE 4

Page 2

Page 2
Image 2
Lennox International Inc 506945-01 Setting the Unit CONTIN­ UED -- Unit Placement, Unit Dimensions Inches MM