Diagnostic error codes
Refer to the following diagnostic error codes when using the diagnostic tests. See
“Running tests” on page 46 for the specific type for information about the
Diagnostic programs.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX
BIOS Test Passed
No action
000-002-XXX
BIOS Timeout
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-024-XXX
BIOS Addressing test failure
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-025-XXX
BIOS Checksum Value error
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-026-XXX
FLASH data error
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-027-XXX
BIOS Configuration/Setup error
1. Run Setup
2. Flash the system. See “Flash update
procedures” on page 209
3. System board
000-034-XXX
BIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Flash update
procedures” on page 209
3. Run memory test
4. System board
000-035-XXX
BIOS Reset Condition detected
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-036-XXX
BIOS Register error
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-038-XXX
BIOS Extension failure
1. Flash the system. See “Flash update
procedures” on page 209
2. Adapter card
3. System board
000-039-XXX
BIOS DMI data error
1. Flash the system. See “Flash update
procedures” on page 209
2. System board
000-195-XXX
BIOS Test aborted by user
Information only
Re-start the test, if necessary
56 Lenovo 3000 J Series