Using the 20/20 AD

Lexicon

 

Realigning Two DAT Recordings

When recording in 4-channel mode to two DAT recorders, it may be useful to record a "clapper" signal to both DATs to facilitate realignment during post- production. When you press ALT-LINK, the 20/20 AD will generate 8mS of silence, followed by an 8-cycle 1 kHz square wave burst at -12dBfs This signal is time-aligned on all four output channels. You can align the two DAT tapes on a disk audio production system by visually lining up the first edge of the burst, or you can align them audibly by subtracting channel 3 from channel 1 and adjusting the offset until the click disppears.

Digital Sinewave Generator

The 20/20 AD includes a digital sinewave generator which is accurate to 20 bits, with a dynamic range of more than 120dB. This generator is useful in testing the digital outputs. To use it:

1.Use the SAMPLE RATE, FORMAT and 4-CHAN buttons to select the output mode. (These controls are locked out in sinewave generator mode.)

2.Press and hold down 1dB SCALE (ALT)and press the 4-CHAN button. 1dB SCALE and 4-CHAN will flash to indicate that the unit will now generate digital sinewaves. The compressor GAIN knob adjusts the frequency of the sine- wave and the THRESHOLD knob adjusts the amplitude, as shown below.

2062.5

3000

5062.5

-18

-16

-14

1500

 

6937.5

-20

 

-12

1125

 

9000

-22

 

-10

937.5

 

11062.5

-24

 

-8

750

 

14062.5

-26

 

-6

562.5

 

17062.5

-30

 

-3

375

187.5

20062.5

-36

-60

0

 

(GAIN)

(THRESHOLD)

 

Frequency in Hz

Level in dBfs

48 kHz Sample Rate

1895

2755

4651

1378

 

 

6374

1033.5

 

 

8269

 

 

861.5

 

 

10163.5

 

 

689

 

 

12920

517

 

 

15676

344.5

172.5

18432.5

(GAIN)

Frequency in Hz

44.1kHz Sample Rate

3.To turn off the sinewave generator, press and hold down 1dB SCALE (ALT) and press 4-CHAN. The 20/20 AD will resume normal operation.

Note that in sinewave generator mode, only the compressor GAIN and THRESHOLD knobs have any effect. Pressing any dual-key combinations other than ALT— 4-CHAN may invoke undocumented diagnostics routines. If you accidentally get into diagnostics mode, the best way to exit is to turn the power off, then on again.

24

Page 28
Image 28
Lexicon 20/20 AD manual Realigning Two DAT Recordings, Digital Sinewave Generator, Gain