1 120
Download 120 pages 11.03 Kb
Page 61
Image 61

Draft document

2-41

Bar Code

Table 2-20: Barcode Length (Continued)

 

 

 

V1, V2 value

 

 

 

Model

 

Dec

Hex

Vertical Pitch

 

 

 

 

 

 

 

 

all barcodes except

24 wire (259X)

12

 

0C

1/180 inch

 

Post-Net a

 

 

 

 

 

 

 

9 wire (248X)

30

 

1E

1/72 inch

 

 

 

 

 

 

 

 

 

Model

 

Dec

 

Hex

long bar height

short bar height

 

 

 

 

 

 

 

 

Post-Net b

24 wire (259X)

288

 

120

 

24/180 inch

8/180 inch

 

9 wire (248X)

270

 

10E

 

18/144 inch

6/144 inch

 

 

 

 

 

 

 

 

a. All the input data is rounded to the multiple value shown. b. Barcode height is fixed to the values shown.

Barcode Control Flag

The control flag is made up of 8 bits as follows:

Table 2-21: Barcode Control Flags

Bit

Description

Decimal

Hexadecimal

Effect

b1

Check Digit

0

00

No check code is generated by the printer.

 

 

 

 

The host computer should generate the

 

 

 

 

check code.

 

 

 

 

 

 

 

1

01

Check code is generated automatically by

 

 

 

 

the printer.

 

 

 

 

 

b2

Human Readable Character

0

00

Print On

 

 

 

 

 

 

 

1

01

Print Off

 

 

 

 

 

b3

EAN-13 (13th digit), UPC-A

0

00

Center

 

(number system character) flag

 

 

 

 

1

01

Under

 

character position

 

 

 

 

 

 

 

 

 

b4-b8

not used

 

 

 

 

 

 

 

 

Setup Barcode Data

This command sets the barcode data on the current printing position.

Format

ESC

[

p

n1

n2

d1

d2

Decimal

27

91

112

n1

n2

d1

d2

Hexadecimal

1B

5B

70

n1

n2

d1

d2