Reference
Set ID
-Use this function to specify a TV ID number.
-Refer to ‘Real Data Mapping’. See page 55.
1.Press the MENU button and then use D / E button to select the
SETUP menu.
2.Press the G button and then use D / E button to select Set ID.
3.Press the G button and then use D / E button to adjust Set ID to choose the desired TV ID number. The adjustment range of Set ID is 1 ~ 99.
4.Press EXIT button to return to TV viewing or press MENU button to return to the previous menu.
EZ Scan
Manual Scan
Channel Edit
DTV Signal
Input Source
Input Label
Set ID | G |
1
Communication Parameters
•Baud rate : 9600 bps (UART)
•Data length : 8 bits
•Parity : None
•Stop bit : 1 bit
•Communication code : ASCII code
* Use a crossed (reverse) cable.
Command Reference List
|
| COMMAND 1 COMMAND 2 | DATA | ||||
|
|
|
|
| (Hexadecimal) | ||
|
|
|
|
|
|
| |
| 01. Power | k | a | 0 | ~ 1 |
| |
| 02. | Input Select | k | b | * (Refer to p.55) |
| |
| 03. Aspect Ratio | k | c | * (Refer to p.55) | |||
| 04. Screen Mute | k | d | 0 | ~ 1 |
| |
| 05. Volume Mute | k | e | 0 | ~ 1 |
| |
| 06. | Volume Control | k | f | 0 | ~ 64 |
|
| 07. | Contrast | k | g | 0 | ~ 64 |
|
| 08. | Brightness | k | h | 0 | ~ 64 |
|
09. | Color | k | i | 0 | ~ 64 |
| |
| 10. Tint | k | j | 0 | ~ 64 |
| |
| 11. Sharpness | k | k | 0 | ~ 64 |
| |
| 12. OSD Select | k | l | 0 | ~ 1 |
| |
13. | Remote Control Lock Mode | k | m | 0 | ~ 1 |
| |
| 14. Treble | k | r | 0 | ~ 64 |
| |
| 15. Bass | k | s | 0 | ~ 64 |
| |
| 16. | Balance | k | t | 0 | ~ 64 |
|
| 17. | Color Temperature | k | u | 0 | ~ 3 |
|
18. | ISM Method | j | p | * (Refer to p.57) | |||
| 19. Low Power | j | q | 0 | ~ 1 |
| |
|
|
|
|
|
|
|
|
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
*[Command 1]: First command to control the set.(j,k,m or x)
*[Command 2]: Second command to control the set.
*[Set ID]: You can adjust the set ID to choose desired monitor ID number in Setup menu. Adjustment range is 1
~99. When selecting Set ID ‘0’, every connected the TV is controlled. Set ID is indicated as decimal (1~99) on menu and as Hexa decimal (0x0~0x63) on transmission/receiving protocol.
*[DATA]: To transmit command data.
Transmit ‘FF’ data to read status of command.
*[Cr]: Carriage Return ASCII code ‘0x0D’
* [ ]: ASCII code ‘space (0x20)’
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
*The Monitor transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
*The Monitor transmits ACK (acknowledgement) based on this format when receiving abnormal data from
Data 1: Illegal Code
2:Not supported function
3:Wait more time
|
| COM- | COM- | DATA 0 | DATA 1 | DATA 2 | DATA 3 | DATA 4 | DATA 5 |
|
|
|
| MAND 1 | MAND 2 | (Hexadecimal) | (Hexadecimal) | (Hexadecimal) | (Hexadecimal) | (Hexadecimal) | (Hexadecimal) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20. Channel Tuning | m | a | physical/program high | major/program low | major low | minor high | minor low | attribute |
|
|
| 21. Channel Add/Del | m | b | 00 ~ 01 |
|
|
|
|
|
|
|
| 22. Key | m | c | key code |
|
|
|
|
|
|
|
| 23. Input Select | x | b | *(Refer to p.58) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
54