LG Electronics 32LS359T, 32LS3590 HI-POT Test, Model name & Serial number D/L, HI-POT auto-check

Models: 32LS350T 32LS359T-ZC 32LS350S-ZA 32LS350S 32LS3590-ZC 32LS359T 32LS350T-ZA 32LS3500-ZA 32LS3590 32LS359S-ZC

1 53
Download 53 pages 7.26 Kb
Page 14
Image 14
5. HI-POT Test

5. HI-POT Test

5.1. HI-POT auto-check preparation

- Check the POWER cable and SIGNAL cable insertion condition

5.2.HI-POT auto-check

(1)Pallet moves in the station. (POWER CORD / AV CORD is tightly inserted)

(2)Connect the AV JACK Tester.

(3)Controller (GWS103-4) on.

(4)HI-POT test (Auto)

-If Test is failed, Buzzer operates.

-If Test is passed, GOOD Lamp on and move to next proc- ess automatically.

5.3.Checkpoint

(1)Test voltage

-Touchable Metal : 3KV / min at 100mA

-SIGNAL : 3KV / min at 100mA

(2)TEST time: 1 second. (case : mass production )

(3)TEST POINT

-Touchable Metal => LIVE & NEUTRAL : Touchable Metal.

-SIGNAL => LIVE & NEUTRAL : SIGNAL.

6.Model name & Serial number D/L

Press "Power on" key of service remote control. (Baud rate : 115200 bps)

Connect RS232 Signal Cable to RS-232 Jack.

Write Serial number by use RS-232.

Must check the serial number at the Product/Service info.. (menu key -> red key -> select product/Service info)

6.1. Signal Table

CMD

LENGTH

ADH

ADL

DATA_1

. . .

Data_n

CS

DELAY

CMD : A0h

LENGTH : 85~94h (1~16 bytes)

ADH : EEPROM Sub Address high (00~1F)

ADL : EEPROM Sub Address low (00~FF)

Data : Write data

CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n

Delay : 20ms

6.2. Comand Set

Adjust mode

CMD(hex)

LENGTH(hex)

Description

EEPROM WRITE

A0h

84h+n

n-bytes Write (n = 1~16)

*Description

FOS Default write : <7mode data> write

Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0, Phase

Data write : Model Name and Serial Number write in EEPROM,.

6.3.Method & notice

(1)Serial number D/L is using of scan equipment.

(2)Setting of scan equipment operated by Manufacturing Technology Group.

(3)Serial number D/L must be conformed when it is produced in production line, because serial number D/L is mandatory by D-book 4.0.

*Manual Download(Model Name and Serial Number)

If the TV set is downloaded by OTA or Service man, sometimes model name or serial number is initialized.(Not always)

There is impossible to download by bar code scan, so It need Manual download.

1)Press the "Instart" key of Adjustment remote control.

2)Go to the menu "6.Model Number D/L" like below photo.

3)Input the Factory model name or Serial number like photo.

4)Check the model name Instart menu. → Factory name displayed. (ex 32LV3400-ZG)

5)Check the Diagnostics.(DTV country only) → Buyer model displayed.(ex 32LV3400-ZG)

Copyright ©

LG Electronics. Inc. All rights reserved.

- 14 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 14
Image 14
LG Electronics 32LS359T HI-POT Test, Model name & Serial number D/L, HI-POT auto-check preparation, Checkpoint, Comand Set