108EXTERNAL CONTROL DEVICE SETUP
EXTERNAL CONTROL DEVICE SETUP
ENGLISH
RS-232C Setup
Connect the
Connect the serial port of the control device to the
Note:
Type of connector;
15
6 |
|
|
| 9 |
|
|
| ||
|
|
| ||
No. |
| Pin name |
1No connection
2RXD (Receive data)
3TXD (Transmit data)
4DTR (DTE side ready)
5GND
6DSR (DCE side ready)
7RTS (Ready to send)
8CTS (Clear to send)
9No Connection
RS-232C Configurations
PCTV
RXD | 2 | 3 | TXD |
TXD | 3 | 2 | RXD |
GND | 5 | 5 | GND |
DTR | 4 | 6 | DSR |
DSR | 6 | 4 | DTR |
RTS | 7 | 8 | CTS |
CTS | 8 | 7 | RTS |
|
|
PCTV
RXD | 2 |
|
|
|
| 3 | TXD |
|
|
| |||||
TXD | 3 |
|
|
| 2 | RXD | |
|
|
| |||||
GND | 5 |
|
|
| 5 | GND | |
|
|
| |||||
DTR | 4 |
|
| 6 | DTR | ||
DSR | 6 |
|
| 4 | DSR | ||
RTS | 7 |
|
| 7 | RTS | ||
CTS | 8 |
|
| 8 | CTS | ||
|
|
|
|
|
|
|
|
|
|
Set ID
Set ID number. “Real Data Mapping” on See p.114
1Press Home to access the main menus.
2Press the Navigation buttons to scroll to OPTION and press OK.
3Press the Navigation buttons to scroll to SET ID and press OK.
4Scroll left or right to select a set ID number and select Close. The adjustment range is
5When you are finished, press EXIT.