CONNECTING ELECTRIC DRYERS (cont.)
USA ONLY
wWARNING:
•Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.
•Grounding through the neutral conductor is prohibited for: (1) new
Four-Wire Connection for Electric Dryers: Direct Wire
•A
•A
1" (2.5 cm)
Ground Wire
5"
(12.7 cm)
•Use UL-listed 4-wire #10 AWG-minimum copper conductor cable.
•Allow at least 5 ft (1.5 m) length to allow for removal and reinstallation of the dryer.
Terminal
Block
Strain Relief
1Remove 5 inches (12.7 cm) of the outer covering from the wire. Remove 5 inches of insulation from the ground wire. Cut off approximately 11⁄2 inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.
2Remove the terminal block access cover on the upper back of the dryer. Install a
hot | Neutral | hot |
(Black) | (White) | (Red) |
Ground Screw
Ground Wire
3Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. TIGhTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
20