CONNECTING ELECTRIC DRYERS (cont.)

USA ONLY

wWARNING:

Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Three-Wire Connection for Electric Dryers: Direct Wire

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1" (2.5 cm)

1Remove 312 inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.

Use UL-listed3-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft (1.5 m) length to allow for removal and reinstallation of the dryer.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed 3-Wire Power Cord

2Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

hot

Neutral

hot

Black)

(White)

(Red)

Ground Screw

Ground Wire

3Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. TIGhTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.

22

Page 22
Image 22
LG Electronics D2702V, D2702W, 3828EL3010Y manual Three-Wire Connection for Electric Dryers Direct Wire